█ Summary:
This automaticspecialized equipment is for testing the electrode of Li-ion battery. Adopt the high-speedvideo system working with the PLC control system, then test the defectiveelectrode, like the followings. The missing coating electrode is no less than0.5mm dia.The deviation of coating size is larger than 5mm. There is scoringand uneven on the coating appearance. The length of tape splicing is abnormal.The deviation of coating misplace is larger than 2mm. Single or double sideelectrode is uncoated. To stick the marking tape on the defective electrode.
█ Features:
l Adoptthe high-speed video system, with high detectionprecision.
l To stick the marking tape on the defective electrode automatically.
l Use the automatic rectifying system and servo motor to wind or unwind.
l Use the pneumatic swing arm to control tension automatically.
l Automatically shut down to warm whilebreakdown and starving happen, then displaying on the interface.
l Adopt the imported PLC control system.
█ TechnicalParameters:
No | Item | Parameter | Unit |
1 | Model | LPC(A)-120-R |
|
2 | Electrode Width | 20~120 | mm |
3 | Electrode Length | 320~2000 | mm |
4 | Material Roll Max Diameter | φ400 | mm |
5 | Material Roll Inner Diameter | Φ76.2(3″) | mm |
6 | Winding Alignment Metric | ±0.5 | mm |
7 | Speed | ≥40 | m/min |
8 | Operating Rate | >98% |
|
9 | Yield Rate | >99% |
|
10 | Weight | 600 | kg |
11 | Dimension | 2000L×1500W×2000H | mm |
Note: The above data is for reference only. Technical happen to change without notice, which is subject to negotiation and contract agreements. |